Shell and Tube Heat Exchanger

Shell and tube heat exchanger from our China factory: TEMA BEM, BEU and AES shells, fixed tube sheet, U-tube and floating head, 8 materials, D1/D2, ISO 9001/14001, export worldwide.

Shell and Tube Heat Exchanger

Shell and Tube Heat Exchanger
Model reference ZG–1493

Shell and Tube Heat Exchanger

Custom-engineered heat exchangers built to your specification

  • TypeShell & tube heat exchanger (fixed / U-tube floating head)
  • Design pressure0.6 / 1.0 / 1.6 / 2.5 MPa (shell side)
  • Design temperature-20 °C to +200 °C (carbon steel); to +250 °C on request
  • Thermal capacity5 kW to 5,000 kW per unit
  • StandardGB/T 151, TEMA, ASME Section VIII Div. 1, HG/T 20592
  • Pressure vessel design
  • ISO 9001 & ISO 14001
  • Drawings issued with every order
01

Overview

A heat exchanger typically involves two flowing fluids separated by a solid wall, and most industrial heat transfer combines conduction through that wall with convection on both faces. We are well versed in the many forms of design and engineer to your specification — choosing the right type, orientation and material set for the duty rather than forcing it into a standard model. Our engineers and production team have built specialised exchangers for a wide range of industries for many years.

A heat exchanger typically involves two flowing fluids separated by a solid wall.  Many of the heat transfer processes encountered in industrial settings involve composite systems or a combination of conduction and convection. Heat is first transferred from the hot fluid to the wall by convection, through the wall by conduction, and from the wall to the cold fluid again by convection. We are well-versed in the many forms of design and can engineer to your specifications. Zhenggong builds custom heat exchangers for several industries. Our team of engineers, designers and production staff have many years of experience.

Key features at a glance

  • Engineered to your duty — no off-the-shelf compromise
  • Full range: shell & tube, plate, finned, condenser, evaporator and air-cooled designs
  • Thermal and mechanical design reviewed by our engineering team before production
  • Materials matched to the fluid, temperature and pressure in service
  • D1 / D2 pressure vessel certification, ISO 9001 and ISO 14001

Delivery scope

Every unit is supplied with a technical data sheet, general arrangement drawing, pressure test / hydrostatic test certificate and material certificates. Supplied item, orientation, nozzles and accessories are confirmed on the GA drawing before manufacture.

02

At a glance

TypeShell & tube heat exchanger (fixed / U-tube floating head)
Design pressure0.6 / 1.0 / 1.6 / 2.5 MPa (shell side)
Design temperature-20 °C to +200 °C (carbon steel); to +250 °C on request
Thermal capacity5 kW to 5,000 kW per unit
StandardGB/T 151, TEMA, ASME Section VIII Div. 1, HG/T 20592

This is a Shell & tube heat exchanger (fixed / U-tube floating head). The specification below is the standard envelope — every dimension, connection and material is finalised against your duty on the general arrangement drawing.

03

Construction & material

Every unit is engineered to the duty. Pick the construction that suits your service and the design envelope below updates. We confirm it against your fluid before the drawing is issued.

Size this construction with the duty calculator →Not sure which material? Send us the fluid and we will recommend one.
04

Technical specifications

TypeFixed tube sheet, U-tube, floating head, plug type
Design pressure0.6 / 1.0 / 1.6 / 2.5 MPa (shell side)
Design temperature-20 °C to +200 °C (carbon steel); to +250 °C on request
Heat transfer surface1 m² to 150 m² per shell
Thermal capacity5 kW to 5,000 kW per unit
Shell diameterΦ200 to Φ1,000 mm
Tube length1,000 to 6,000 mm
Tube sizeΦ19 / Φ25 / Φ32 mm, wall 1.0 / 1.5 / 2.0 mm
ConnectionsDN15 to DN200, flanged (HG/T 20592) or welded
ConstructionCarbon steel, SS304 / SS316L, titanium, copper alloy, lined
Insulation50 mm rock wool with aluminium cladding (optional)
Engineering scopeThermal design, mechanical design, material selection, documentation
DocumentationGA drawings, material certificates, hydro test reports
05

Features

01Engineered to your duty — no off-the-shelf compromise
02Full range: shell & tube, plate, finned, condenser, evaporator and air-cooled designs
03Thermal and mechanical design reviewed by our engineering team before production
04Materials matched to the fluid, temperature and pressure in service
05D1 / D2 pressure vessel certification, ISO 9001 and ISO 14001
06

Applications

Select a service to see which construction suits it.

07

Standards & certification

GB/T 151, TEMA, ASME Section VIII Div. 1, HG/T 20592

  • Pressure Vessel Class D1 / D2
  • ISO 9001
  • ISO 14001
08

Frequently asked questions

Can you design something non-standard?
That is most of what we do. Send the duty — fluids, flow rates, temperatures, pressures and the space available — and we will propose the construction and the calculation.
Do you sign off the thermal calculation?
Yes. The duty calculation and the resulting surface area are issued with the quotation and shown on the GA drawing.
10

Request a quotation

Tell us the duty and we will return a budgetary offer with a GA drawing, material specification and lead time.

Preview the attached specification
Typical reply within 1 working day. Your details are used only to answer this enquiry.

Save to list