Shell and Tube Heat Exchanger
Custom-engineered heat exchangers built to your specification
- TypeShell & tube heat exchanger (fixed / U-tube floating head)
- Design pressure0.6 / 1.0 / 1.6 / 2.5 MPa (shell side)
- Design temperature-20 °C to +200 °C (carbon steel); to +250 °C on request
- Thermal capacity5 kW to 5,000 kW per unit
- StandardGB/T 151, TEMA, ASME Section VIII Div. 1, HG/T 20592
- Pressure vessel design
- ISO 9001 & ISO 14001
- Drawings issued with every order
Overview
A heat exchanger typically involves two flowing fluids separated by a solid wall, and most industrial heat transfer combines conduction through that wall with convection on both faces. We are well versed in the many forms of design and engineer to your specification — choosing the right type, orientation and material set for the duty rather than forcing it into a standard model. Our engineers and production team have built specialised exchangers for a wide range of industries for many years.
A heat exchanger typically involves two flowing fluids separated by a solid wall. Many of the heat transfer processes encountered in industrial settings involve composite systems or a combination of conduction and convection. Heat is first transferred from the hot fluid to the wall by convection, through the wall by conduction, and from the wall to the cold fluid again by convection. We are well-versed in the many forms of design and can engineer to your specifications. Zhenggong builds custom heat exchangers for several industries. Our team of engineers, designers and production staff have many years of experience.
Key features at a glance
- Engineered to your duty — no off-the-shelf compromise
- Full range: shell & tube, plate, finned, condenser, evaporator and air-cooled designs
- Thermal and mechanical design reviewed by our engineering team before production
- Materials matched to the fluid, temperature and pressure in service
- D1 / D2 pressure vessel certification, ISO 9001 and ISO 14001
Delivery scope
Every unit is supplied with a technical data sheet, general arrangement drawing, pressure test / hydrostatic test certificate and material certificates. Supplied item, orientation, nozzles and accessories are confirmed on the GA drawing before manufacture.
At a glance
This is a Shell & tube heat exchanger (fixed / U-tube floating head). The specification below is the standard envelope — every dimension, connection and material is finalised against your duty on the general arrangement drawing.
Construction & material
Every unit is engineered to the duty. Pick the construction that suits your service and the design envelope below updates. We confirm it against your fluid before the drawing is issued.
Technical specifications
| Type | Fixed tube sheet, U-tube, floating head, plug type |
|---|---|
| Design pressure | 0.6 / 1.0 / 1.6 / 2.5 MPa (shell side) |
| Design temperature | -20 °C to +200 °C (carbon steel); to +250 °C on request |
| Heat transfer surface | 1 m² to 150 m² per shell |
| Thermal capacity | 5 kW to 5,000 kW per unit |
| Shell diameter | Φ200 to Φ1,000 mm |
| Tube length | 1,000 to 6,000 mm |
| Tube size | Φ19 / Φ25 / Φ32 mm, wall 1.0 / 1.5 / 2.0 mm |
| Connections | DN15 to DN200, flanged (HG/T 20592) or welded |
| Construction | Carbon steel, SS304 / SS316L, titanium, copper alloy, lined |
| Insulation | 50 mm rock wool with aluminium cladding (optional) |
| Engineering scope | Thermal design, mechanical design, material selection, documentation |
| Documentation | GA drawings, material certificates, hydro test reports |
Features
Applications
Select a service to see which construction suits it.
Standards & certification
GB/T 151, TEMA, ASME Section VIII Div. 1, HG/T 20592
Frequently asked questions
Can you design something non-standard?
Do you sign off the thermal calculation?
Request a quotation
Tell us the duty and we will return a budgetary offer with a GA drawing, material specification and lead time.